Install cover tube and wall flange to supply pipe, Install control stop – Sloan 310 Foot Pedal Flushometer User Manual
Page 3
![background image](https://www.manualsdir.com/files/804928/content/doc003.png)
3
1
Install Optional Sweat Solder
Adapter (only if your supply pipe
does not have a male thread)
2
Install Cover Tube and Wall Flange
to supply pipe
With the exception of Control Stop Inlet, DO NOT use pipe
sealant or plumbing grease on any valve component or
coupling!
!!! IMPORTANT !!!
Protect the chrome or special finish of Sloan Flushometers —
DO NOT USE toothed tools to install or service these valves.
Use a Sloan A-50 Super-Wrench™, Sloan A-109 Plier Wrench
or smooth jawed spud wrench to secure all couplings. Also
see “Care and Cleaning” section of this manual.
!!! IMPORTANT !!!
This product contains mechanical and/or electrical
components that are subject to normal wear. These
components should be checked on a regular basis and
replaced as needed to maintain the valve’s performance.
!!! IMPORTANT !!!
If you have questions about how to install your Sloan
Flushometer, consult your local Sloan Representative or call
Sloan Installation Engineering Department at:
1-888-SLOAN-14 (1-888-756-2614) OR 1-847-233-2016
A
Measure from finished
wall to C/L of Fixture
Spud. Cut pipe 1¼"
(32 mm) shorter than
this measurement.
Chamfer O.D. and I.D.
of water supply pipe.
WATER SUPPLY PIPE
FINISHED WALL
1-1/4”
(32 mm)
C/L OF
FIXTURE
SPUD
SWEAT
SOLDER
ADAPTER
B
Slide Threaded Adapter
fully onto pipe.
C
Sweat solder the
Adapter to pipe.
Thread Control Stop onto supply pipe. Tighten with a wrench until
outlet is positioned as required.
WATER
SUPPLY PIPE
SWEAT
SOLDER ADAPTER
COVER TUBE
WALL
FLANGE
SET SCREW
A
Measure from finished wall to first thread of Adapter or threaded
supply pipe (dimension “X”). Cut Cover Tube to this length.
B
Slide Cover Tube over pipe. Slide Wall Flange over Cover Tube
until against wall.
A
Tighten Set Screw with a 1/16” hex wrench. For Exposed
Flushometers — DO NOT install Vandal Resistant Stop Cap at this
time.
B
3
Install Control Stop
CONCEALED
EXPOSED
SET
SCREW
SUPPLY
FLANGE
IRON PIPE NIPPLE OR COPPER PIPE
WITH SWEAT SOLDER ADAPTER
COVERING
TUBE
BAK-CHEK
®
CONTROL
STOP
BAK-CHEK
®
CONTROL STOP
IRON PIPE NIPPLE OR
COPPER PIPE WITH
SWEAT SOLDER
ADAPTER
Never open Control Stop to where the flow from the valve
exceeds the flow capability of the fixture. In the event of a
valve failure, the fixture must be able to accommodate a
continuous flow from the valve.
!!! IMPORTANT !!!