beautypg.com

Output #2 control, Answer detect, Double confirmation – Skutch Electronics AS-80 User Manual

Page 7: Announcement, Remote programming

background image

time designated by this parameter. The second
way that the OUTPUT can be triggered is by
switching it "ON" in programming mode. Here
again the OUTPUT will only stay high as
specified by this parameter. If this parameter is
set to 99, then the OUTPUT will stay "ON"
until it is turned "OFF" in program mode, or
until the RESET button on the AS-80 is
depressed, or until power is removed from the
AS-80.

The parameter is entered as tenths of

minutes. This means that an entry of 01 would
equal one tenth of a minute or 6 seconds. An
entry of 20 would represent 2 minutes while an
entry of 35 would represent a time of 3.5
minutes or 3 minutes 30 seconds. This can be
set from 01 to 98; the default is 10.

Output #2 Control

This parameter controls how long OUTPUT

#2 stays "ON" after it has been triggered.
OUTPUT #2 can be triggered two different
ways. The first way is by triggering the channel
by shorting the input for 200mili-seconds or
longer. Once the input has been triggered, there
is a 10 second buffer before the OUTPUT goes
high. After the 10 second buffer period, the
OUTPUT is triggered and stays high for the
time designated by this parameter. The second
way that the OUTPUT can be triggered is by
switching it "ON" in programming mode. Here
again the OUTPUT will only stay high as
specified by this parameter. If this parameter is
set to 99, then the OUTPUT will stay "ON"
until it is turned "OFF" in program mode, or
until the RESET button on the AS-80 is
depressed, or until power is removed from the
AS-80.

The parameter is entered as tenths of

minutes. This means that an entry of 01 would
equal one tenth of a minute or 6 seconds. An
entry of 20 would represent 2 minutes while an
entry of 35 would represent a time of 3.5
minutes or 3 minutes 30 seconds. This can be
set from 01 to 98; the default is 10.

Answer Detect

This parameter controls how the AS-80 will

detect a CONFIRMED condition. The
DEFAULT is mode 2 which is the Normal
Answer Detect. In mode 2 the unit will call the

number, if the line is BUSY, or if the phone is
not answered by the 5th ring, the AS-80 will
consider the call not confirmed. If it detects that
the call has been answered, it will deliver the
pre-recorded announcement. Mode 1 works the
same but has more noise immunity built into it.
Mode 1 should be used if you should experience
frequent false answer detect in mode 1.

In mode 0, the AS-80 will dial the number,

waits approximately 7.5 seconds , then will
deliver the announcement. At the end of the
Announcement the AS-80 will BEEP and wait 6
seconds for a touch tone 1 to be dialed. The
called party must dial a touch tone 1 either
during the announcement or during the 6 second
silent period to cause a call to be CONFIRMED.
This can be set from 0 to 2; the default is 2.

Double Confirmation

When Double Confirmation is enabled, the

unit must detect two CONFIRMATION
conditions for each phone number, before it will
consider the call CONFIRMED. This can be set
0 for one confirmation or 1 for double
confirmation; the default is 0.

Announcement

In the announcement section you may

either test announcements or record new
announcements for either or both channels.
Each channel has a variable length
Announcement from 1 to 28 seconds in length.
During playback you can stop the
announcement by pressing the 1 touch tone.

1# = Playback Channel 1 Message
2# = Playback Channel 2 Message
*1# = Record Channel 1 Message.

Press # to end.

*2# = Record Channel 2 Message.

Press # to end.

# = To Bypass

After you have finished with the

Announcement section you will hear a solid
tone. At this point turn the program switch back
to the NORMAL position and you have finished
the program process.