Page 5: For the plumber

background image

Installation

For The Plumber

Begin by planning the installation and obtaining the
needed supplies:

3

8

" soft copper tubing

3

4

" rigid drain tubing

3

4

" FPT fitting for bin/reservoir drain connection

1

2

" FPT fitting for condenser drain connection

3

8

" FPT fitting for water cooled condenser inlet

connection

1. Connect cold potable water to the

3

8

" male flare

at the back of the cabinet. A water filter and hand
shut off valve is recommended. Flush the water
line prior to connecting to the ice machine.

If water cooled, connect a separate water inlet line
to the water cooled condenser inlet fitting. It should
also have a hand shut off valve.

A loop of copper tubing may be used between the
ice machine and the water supply. This will allow
the ice machine to be pulled out from its installed
location without disconnecting the water line. No
back-flow preventer should be needed in the inlet
potable water line because provision for that is
incorporated in this N.S.F. listed product (the water
valve outlet is above the reservoir wall and cannot
siphon).

2. Connect a drain tube to each drain connection
(water cooled drain must be separate).

3. Route the drain tubes to the building drain
receptacle.

SCE275

January 2003

Page 5

CONFORM TO ALL LOCAL CODES

Plumbing Connections,

Water Cooled Shown

Water Cooled Inlet

Water Cooled Drain

Reservoir & Bin

Drain

Potable Water Inlet

Drain Receptacle