beautypg.com

How to operate the autoiq controller 15, Sce275, How to operate the autoiq controller – Scotsman SCE275 User Manual

Page 15

background image

SCE275

January 2003

Page 15

How To Operate The AutoIQ Controller

The AutoIQ Controller is a microprocessor based
device that receives input from several sources
and switches various components on and off.

Its manual control is thru the use of the Push
Button Control Switches

1. Freeze Button. Pushing and releasing this
button starts or restarts the machine. The AutoIQ
Controller remembers what cycle it was last in and
returns to that cycle.

2. Harvest Button: Pushing and releasing this
button will cause the machine to go directly to a
Harvest Cycle. Can be done from Freeze or Off.
The machine will switch Off at the end of the
Harvest cycle.

3. Clean Button: Pushing and releasing this button
will cause the machine to only power the water
pump for circulation of ice machine cleaner. After
the ice machine cleaner has
circulated for about 10
minutes, a second push of this
button will switch on the
rinsing system to flush out the
dissolved scale and ice
machine cleaner.

4. Off Button: Pushing and
releasing this button will
switch the machine OFF at the
end of the next cycle. If the
button is pushed and HELD
for more than 3 seconds, the
unit will switch off immediately.

To Reset: First push and
release the Off button, then
push and release the Freeze
button.

1

2

3

4

5

6

7

8

9

BIN FULL

FREEZE

HARVEST

CLEAN

OFF

WATER
REFRIGERATION

RESERVOIR WATER

LEVEL SENSOR

BIN CONTROL SENSOR

BIN CONTROL SENSOR

RESERVOIR & DISCHARGE

LINE THERMISTORS

LOW VOLTAGE IN/OUT

WATER VALVE

HOT GAS VALVE

CONTACTOR COIL

STACKING

FUTURE USE

FACTORY USE

PUSH BUTTON

CONTROL SWITCHES

HI VOLTAGE IN/OUT

WATER PUMP

AIR COOLED FAN MOTOR

INDICATOR LIGHTS:

ERROR LIGHTS: