Problem or Symptom

Possible Cause

Probable Correction

Machine is off

Bin is full, ice in cube port

Use some ice

Power is off, check LEDs.

If all lights are out, check power supply, restore
power if off

Transformer is open

If all lights are out and there is power, check
transformer output for 24 vac

Unit has been switched off
or has finished a Clean
cycle, Off Light is glowing

Push and release Freeze button

Unit has Shut Down

Check for Refrigeration or Water Error

Unit is off on a Water
Error

Water inlet valve
malfunction

Check water Light, if the Light blinks 2 times and
repeats, check the water inlet valve for proper
water flow.**

Water pump malfunction

Check that pump hose is attached and if pump is
plugged in and working.

Water level sensor may
have failed.

Check float stem, reset machine. If it will not
reset or gives another water error and everything
else is OK, replace the water level sensor.

Unit is off on a
Refrigeration Error

Low discharge or long
freeze cycle

Check refrigeration Light. If the Light is glowing,
there is a probable refrigeration problem or on
water cooled a water interruption

Harvest problem

Check refrigeration Light. If the Light blinks once
and repeats, look for a harvest problem.** This
also indicates that cubes were sensed by the bin
controls.

If the light blinks 2 times and repeats, check for a
harvest error - no cubes sensed.

High Discharge Temp

Check refrigeration Light. If the Light blinks 3
times and then repeats, check for a reason for
high discharge temperatures - such as a bad fan
motor or very hot ambient.

Unit does not go into
harvest - exceeds
maximum freeze time

Push and release Off button. Push and release
Freeze button. Check operation.

Push cube size float down and check operation.

Unit runs and both
Error Lights are ON

Temperature sensors out
of range

Replace the temperature sensor set (water and
discharge).

Same, but 1 light is on

Reservoir temp. wrong

Check water temp and sensor.

* Machine may be reset by pushing and releasing the Off button, then pushing and releasing the Freeze
button. ** See following pages

Service Diagnosis

Proper service diagnosis begins with observation, comparing the complaint to the operation of the unit. Ice
machine service diagnosis should proceed from water, to electrical and then to refrigeration.