Problem or Symptom

Possible Cause

Probable Correction

Fan motor(s) do not
turn.

Open motor windings, or
seized bearings, or blade
stuck against shroud

Replace fan motor or free fan blade.

No power to fan motors

Fan motor unplugged, check for voltage at
controller. Controller cycles fan motors during
freeze. If no voltage to the fan motors at
controller during freeze, replace controller.

Pump motor does not
turn

Open motor windings, or
seized bearings

Replace pump

No power to pump

Check electrical connections. Check water level.
Switch the unit to Clean, the pump should then
have power to it. If not, replace the AutoIQ
Controller.

Hot Gas Valve does
not open.

Open solenoid coil.

Replace hot gas valve

Stuck valve

Replace hot gas valve

No power to coil in Harvest

Check wire connections, if ok, replace AutoIQ
Controller

Hot Gas Valve leaks
thru (warm tube
temperatures on both
sides of valve during
freeze)

Mechanical problem in
valve

Replace valve

Water Inlet Valve does
not open

Open solenoid coil

Replace valve

Stuck valve

Replace valve

No power to valve (early
part of harvest)

Check wire connections, if ok, replace AutoIQ
Controller

Water Inlet Valve does
not flow enough water

Restriction in water supply

Check water filters and/or inlet screen.

Water Inlet Valve
leaks thru

Mechanical problem in
valve

Replace valve

Compressor does not
work

Unit in Clean cycle

Push and release Freeze button.

Contactor coil open

Replace contactor

Open starting components

Check and replace

Open windings

Check and replace compressor

Internal valve failure