FOR THE PLUMBER

CONFORM TO ALL APPLICABLE CODES

Water Inlet

Connect the ice machine to cold

potable water. Use 3/8" O.D. copper

tubing, and connect to the 3/8" male

flare at the back of the cabinet. Install

a hand valve near the machine to

control the water supply.

Drains

There is one 3/4" FPT drain at the

back of the cabinet, the drain line is of

the gravity type, and 1/4 inch per foot

fall is an acceptable pitch for the drain

tubing. Install a vent at the highest

point of the drain line, and the ideal

drain receptacle would be a trapped

and vented floor drain.

Use only 3/4" rigid tubing.

Storage Bin: Install a separate

gravity type drain. Insulation of this

drain line is recommended.

NME1854R & FME2404R

January 2000

Page 9

FLOOR DRAIN

VENT BIN DRAIN

3/4" FPT

VENT ICE

MACHINE

DRAIN,

3/4" FPT

WATER INLET

3/8" MALE

FLARE

FIELD SUPPLIED

WATER FILTER

HAND SHUT

OFF VALVE

CONNECT TO

COLD WATER