FOR THE ELECTRICIAN

CONFORM TO ALL APPLICABLE CODES

Connect electrical power to the wires in the

junction box at the rear of the machine.

Check the nameplate (located on the back panel)

for the voltage requirements, and for the minimum

circuit ampacity. The machine requires a solid

chassis to earth ground wire.

The Ice Machine should be connected to its own

electrical circuit so it would be individually fused.

Voltage variation must remain within design

limitations, even under starting conditions.

Electrically the remote condenser fan motor is

connected to the Ice Machine at the contactor

terminals for the compressor and the fan motor

operates whenever the compressor operates.

Electrical connections are made at the junction

box at the back of the Ice Machine and at the

junction box on the remote condenser.

The remote condenser must be wired to the Ice

Machine in accordance with local and national

electrical codes with a minimum of 18 Awg. wire

with an ground bonding wire connected to the

ground screws provided in both the condenser and

machine field wiring boxes. All outdoor wiring must

be in rain proof conduit.

All external wiring must conform to national,

state, and local electrical codes. The use of a

licensed electrician is required to perform the

electrical installation.

NME1854R & FME2404R

January 2000

Page 10

TERMINAL STRIP

FOR REMOTE

CONDENSER

ICE MACHINE

JUNCTION BOX

POWER

SUPPLY

GROUND

THE

CHASSIS

RAIN PROOF

CONDUIT