OPERATION: Refrigeration

At the compressor, refrigerant is compressed into

a high temperature gas. The discharge line directs

this gas to the condenser. At the remote

condenser the gas is cooled by air and it then

condenses into a liquid. This high pressure liquid

then goes through the liquid line to the head

pressure control valve, into the receiver, through

the liquid line valve and then through the

expansion valve.

The thermostatic expansion valve meters liquid

refrigerant into the evaporator, the volume of liquid

refrigerant depending upon the temperature of the

evaporator; warmer evaporators get more

refrigerant and colder evaporators get less.

At the evaporator, the refrigerant enters an area of

relatively low pressure, where it can easily “boil off”

or evaporate. As it evaporates, it absorbs heat

from the evaporator and whatever is in contact with

it (such as the water inside it). After the

evaporator, the refrigerant, now a low pressure

vapor, goes through the suction line back to

compressor, where the cycle is repeated.

NME1854R & FME2404R

January 2000

Page 19

REMOTE CONDENSER

DETAIL OF HEAD

PRESSURE CONTROL

VALVE

EVAPORATOR

DISCHARGE

LINE

LIQUID LINE

HEAD

PRESSURE

CONTROL

VALVE

RECEIVER

COMPRESSOR

Refrigeration Schematic

KING

VALVE

SUCTION

LINE

THERMOSTATIC

EXPANSION

VALVE

LIQUID LINE

VALVE

There are two separate refrigeration systems in this machine.