Bin Control: Installation

The bin control is a thermostat. It must be field
installed after the ice machine has been placed on
the bin.

Before starting, remove the left front panel and any
baffle in the bin.

1. Locate bin thermostat bulb.

2. Route bulb thru routing tube (located between
the compressor and the reservoir).

3. Locate bin thermostat bracket.

4. Carefully position the thermostat bulb on the
bracket (see the diagram on the next page).

5. Fasten the bracket to the bottom of the ice
machine with the two 3-pronged knobs supplied
with the unit.

6. Pull back into the ice machine any excess
capillary tubing.

7. Return the baffle to the bin and continue with
the installation.

Note: If the machine is located at an altitude higher
than 2,000 ft., adjust the thermostat by removing
the plastic cover and rotating the adjustment screw
per the table.

Bin Thermostat Bulb

Thermostat

Bulb

Routing

Tube

Route Bin Thermostat Bulb Into Bin

Bin Thermostat Altitude Correction Table

CW Turns of Range Screw (under plastic cover)

Feet

Turns

Feet

Turns

2000

55

o

8000

340

o

4000

160

o

9000

385

o

6000

250

o

10000

405

o

Use This Table to Adjust Thermostat

Bin

Thermostat

Body

CME1356 and CME1656

May 2000

Page 9

This manual is related to the following products: