Operational Characteristics: CME1656

Cycle Times (minutes):

System Pressures (PSIG):

Refrigerant Charge, R-404A

Air cooled: 64 ounces

Water cooled: 62 ounces (A thru E series)

Water cooled: 58 ounces (F series)

Typical Air Cooled Machine Amps

Single Phase

5 minutes into freeze: 17

Harvest: 15.5

Three Phase

5 minutes into freeze: 11

Harvest: 9

Typical Harvest Ice Weight

19.2 lb

Superheat (near the end of freeze)

The TXV will control a nominal superheat
point that can vary unit to unit from 11

o

F. to

17

o

F. While controlling that point the

superheat can also range + or - 4

o

F. without

affecting performance.

Water Cooled:

Discharge Pressure: 245 PSIG

Hi Pressure Cuts Out at: 450 PSIG

Air Cooled

70

o

F. indoor air, 50

o

F. water

90

o

F. indoor air, 70

o

F. water

Freeze

15 - 17

18 - 20

Harvest

3

2 ½

Water Cooled

70

o

F. indoor air, 50

o

F. water

90

o

F. indoor air, 70

o

F. water

Freeze

14 - 16

16 - 17

Harvest

2 ½

2 ½

Air Cooled

70

o

F. indoor air, 50

o

F. water

90

o

F. indoor air, 70

o

F. water

Suction: End of Freeze

21 - 23

34 - 36

Suction: Peak in Harvest

88 - 92

101 - 105

Discharge: 5 minutes into Freeze

210 - 220

285 - 295

Discharge: Minimum in Harvest

115 - 125

165 - 175

Water Cooled

70

o

F. indoor air, 50

o

F. water

90

o

F. indoor air, 70

o

F. water

Suction: End of Freeze

31 - 34

31 - 34

Suction: Peak in Harvest

75 - 85

80 - 90

Discharge:

245

245

CME1356 and CME1656