beautypg.com

Scotsman CME1356 User Manual

Page 15

background image

AutoIQ Controller

Indicator Lights:

Bin Full: On when bin is full, goes on and
off as ice falls during a harvest cycle.

Freeze: On when the unit is in the Freeze
cycle, blinks when a freeze mode is pending.

Harvest: On when the unit is in the Harvest
cycle.

Clean: On when the unit is in the Clean
cycle, blinks when preparing for a clean
mode.

Off: On when the unit has been switched
off, blinks when the machine is preparing to
shut off.

Water: On when the controller has identified
a problem with the water system.

Refrigeration: On when the controller has
identified a problem with the refrigeration
system.

Cycle Definitions:

Freeze: The refrigeration system is operating
to remove heat from the evaporators. The
compressor, fan motor (if air cooled) and
water pump are ON.

Harvest: The refrigeration and water
systems are operating to harvest the ice
cubes. While the compressor is on for the full
cycle, the water pump will be off at the
beginning and inlet water valve will switch off
before the end.

Clean: The Inlet Water Valve opens to fill the
reservoir. The Water Pump starts. The Clean
indicator light is switched ON. A manually
initiated rinse flushes the system.

1

2

3

4

5

6

7

8

9

BIN FULL

FREEZE

HARVEST

CLEAN

OFF

WATER

REFRIGERATION

RESERVOIR WATER

LEVEL SENSOR

ICE SENSOR

ICE SENSOR

RESERVOIR & DISCHARGE

LINE THERMISTORS

LOW VOLTAGE IN/OUT

WATER VALVE

HOT GAS VALVE

PURGE VALVE TIMER

CONTACTOR COIL

STACKING and/or

THERMOSTAT

FUTURE USE

FACTORY USE

PUSH BUTTON

CONTROL SWITCHES

HI VOLTAGE IN/OUT

WATER PUMP

INDICATOR LIGHTS:

DIAGNOSTIC LIGHTS:

CME1356 and CME1656

May 2000

Page 15

This manual is related to the following products: