Specifications

These ice machines are designed to be installed

indoors, in a controlled environment. They can

operate satisfactorily under a wide variety of

conditions. Do NOT operate the machine in

temperatures it has not been designed for. Do

NOT operate the machine above or below the

voltage limits for the particular model. Do NOT

operate the machine with too little or too much

water pressure.

Operational Limits

Minimum

Maximum

Air Temperature

50

o

F.

100

o

F.

Water Temperature

40

o

F.

100

o

F.

Water Pressure

20 psi

80 psi

Voltage (60 Hz model)

198

253

Voltage (50 Hz model)

207

253

Inlet water flow required is 2.7 GPM.

A stacking kit, for like models, is KSCME6-LG-B

Voltage note: The control system transformer in

the control box of this ice machine has two primary

taps, one for 208 volt power and one for 240 volt

power. The machine ships with the power supply

connected to the 208 volt tap. Change to the 240

volt tap when the voltage supplied to the unit is

greater than 229 volts

All models will fit a standard, 48" wide Scotsman

Ice Storage Bin. Some examples are BH900,

BH1100, BH1300, BH1600. There may be other

bins that can be used, check Scotsman’s sales

literature for application information. Slope front

bins must have an internal baffle like the BH900.

Baffle must be approximately in the position shown

in the diagram on page 5.

Scotsman reserves the right to make design

changes and/or improvements at any time.

Specifications and designs are subject to change

without notice.

Dateplates on the ice machine contain charge and

electrical requirements. Always go by the dataplate

information. The table below is for reference.

Model Number

Model

Series

Dimensions

W" x D" x H"

(w/o bin)

Basic

Electrical

Condenser

Type

Minimum

Circuit

Ampacity

Maximum

Fuse

Size

Refrigerant

Charge

(R-404A)

CME1356AS-32 A thru E 48 ½ x 24 x 28 208-230/60/1 Air Cooled

26.7

30

64 ounces

CME1356WS-32 A thru E same

208-230/60/1 Water Cooled

23.9

30

62 ounces

CME1356WS-32 F

same

208-230/60/1 Water Cooled

23.9

30

58 ounces

CME1356AS-3

A thru E same

208-230/60/3 Air Cooled

17.8

20

64 ounces

CME1356WS-3

A thru E same

208-230/60/3 Water Cooled

14.9

20

62 ounces

CME1356WS-3

F

same

208-230/60/3 Water Cooled

14.9

20

58 ounces

CME1356AS-6

A thru E same

230/50/1

Air Cooled

26.7

30

64 ounces

CME1356WS-6

A thru E same

230/50/1

Water Cooled

23.9

30

62 ounces

CME1356WS-6

F

same

230/50/1

Water Cooled

23.9

30

58 ounces

CME1656AS-32 A thru D same

208-230/60/1 Air Cooled

26.7

30

64 ounces

CME1656WS-32 A thru E same

208-230/60/1 Water Cooled

23.9

30

62 ounces

CME1656WS-32 F

same

208-230/60/1 Water Cooled

23.9

30

58 ounces

CME1656AS-3

A thru E same

208-230/60/3 Air Cooled

17.8

20

64 ounces

CME1656WS-3

A thru E same

208-230/60/3 Water Cooled

14.9

20

62 ounces

CME1656WS-3

F

same

208-230/60/3 Water Cooled

14.9

20

58 ounces

CME1656AS-6

A thru E same

230/50/1

Air Cooled

26.7

30

64 ounces

CME1656WS-6

A thru E same

230/50/1

Water Cooled

23.9

30

62 ounces

CME1656WS-6

F

same

230/50/1

Water Cooled

23.9

30

58 ounces

Basic Information

CME1356 and CME1656

November 2004