beautypg.com

Removal and replacement – Scotsman CME1356 User Manual

Page 35

background image

Removal and Replacement

Water Pump

1.

Disconnect the electrical power.

2. Remove the left front panel.

3. Check that controller lights are out.

4. Unplug water pump from its electrical
connection.

5. Remove 1 plastic bolt and the reservoir cover.

6. Lift water pump up and disconnect outlet tube.

7. Pull float ball from float stem (it is a snap fit).
Pull stem out.

8. Locate water level sensor mounting tabs,
compress together to release sensor from bracket.

9. Remove water pump brackets from pump.

10. Reverse to replace.

11. Replace front panel.

12. Re-connect electrical power.

Inlet Water Valve

1. Remove the left front panel.

2. Shut off the water supply.

3. Push and release the OFF button.

4. Pull the wire harness off the inlet water valve.

5. Remove screws holding the inlet water valve to
the cabinet.

6. Pull the valve away from the cabinet and
disconnect the outlet tube.

7. Unscrew the water valve from the water inlet
tubing.

8. Reverse to reassemble.

9. Push and release the Freeze button

10. Return the left front panel to its original position
and secure it to the cabinet.

Electrical Shock Hazard

Disconnect electrical
power before beginning
service

CME1356 and CME1656

May 2000

Page 35

This manual is related to the following products: