Electrical – Scotsman CME1356 User Manual
Page 12

Electrical
All models must be installed with the correct wire
size and type per the National Electric Code.
Locate the nameplate on the back of the cabinet
and find the numbers for Voltage, Phase, Minimum
Circuit Ampacity and Maximum Fuse Size. Either
fuses or HACR type circuit breakers may be used.
Electrical connections are made in the junction box
in the back of the cabinet.
1. Remove the junction box cover.
2. Knock out 1 hole for a field supplied strain relief.
3. Install wires and strain relief per code.
4. Connect to wires and secure ground wire to
ground screw inside the junction box.
Follow all Local, State and National codes.
Water Cooled Model Shown
Electrical
Power Supply
Condenser
Water
Supply
Condenser
Drain
Junction Box
CME1356 and CME1656
May 2000
Page 12