beautypg.com

Cleaning, sanitation and maintenance – Scotsman C0522R User Manual

Page 22

background image

January 2014

Page 21

C0522 through C1030

Remote Condenser Models - User Manual
Cleaning, Sanitation and Maintenance

This ice system requires three types of maintenance:
• Remove the build up of mineral scale from the ice machine’s water system and sensors.
• Sanitize the ice machine’s water system and the ice storage bin or dispenser.
• Clean the remote condenser.
It is the User’s responsibility to keep the ice machine and ice storage bin in a sanitary condition. Without

human intervention, sanitation will not be maintained. Ice machines also require occasional cleaning of their

water systems with a specifically designed chemical. This chemical dissolves mineral build up that forms during

the ice making process.

Sanitize the ice storage bin as frequently as local health codes require, and every time the ice machine is

cleaned and sanitized.

The ice machine’s water system should be cleaned and sanitized a minimum of twice per year.

1. Remove the front panel.

2. Remove the evaporator cover.

3. If the machine is operating, push and release the

Harvest button. When the machine completes the

Harvest cycle it will stop. If the bin is full (b shows

in display) push and release the Off button.

4. Remove all ice from the storage bin or dispenser.

5. Push and release the Clean button. The yellow

Clean light will blink and the display will show C.

The machine will drain the reservoir and refill it.

Go onto the next step when the purge valve light

has gone out or the reservoir has filled.

6. Pour 8 ounces of Scotsman Clear 1 ice machine

scale remover into the reservoir.

7. Allow the ice machine scale remover to circulate

in the water system for at least 10 minutes.

8. Push and release the Clean button again. The

yellow Clean light will be on continuously and the

machine will drain and refill the reservoir to flush

out the ice machine scale remover and residue.

9. Allow the drain and refill process to continue for at

least 20 minutes.

10. Push and release the Off button. The clean cycle

will stop and the display will show O.

Note: if the machine has not been de-scaled for an

extended period of time and has significant mineral

scale remaining, repeat steps 5-10.

11. Mix a cleaning solution of 1 oz of ice machine

scale remover to 12 ounces of water.

12. Locate curtain, push in on edge of curtain by pivot

pin to release it. Pull each curtain out of machine.

Push Here

Ice machine cleaner contains

acids. Acids can cause burns.

If concentrated cleaner comes

in contact with skin, flush with

water. If swallowed, do NOT

induce vomiting. Give large

amounts of water or milk. Call

Physician immediately. Keep

out of the reach of children.

This manual is related to the following products: