Remote Condenser Models - User Manual
Plumbing Requirements

All models require connection to cold, potable water.

A hand actuated valve within site of the machine

is required. There is a single 3/8” FPT inlet water

connection.

Water Filters Install a new cartridge if the filters were

used with a prior machine.

All models require drain tubing to be attached to them.

There is a single ¾” FPT drain fitting in the back of the

cabinet.

Install new tubing when replacing a prior ice machine,

as the tubing will have been sized for the old model

and might not be correct for this one.

1. Connect water supply to water inlet fitting.

Note: This NSF listed model has a 1" anti-back flow

air gap between the potable water inlet tube end and

the highest possible reservoir water level, no back

flow device is required.

2. Connect drain tubing to drain fitting.

3. Route the drain tubing to building drain. Follow

local codes for drain air gap.

Use rigid drain tubes and route them separately – do

not Tee into the bin’s drain.

Vent the reservoir drain. A vertical vent at the back of

the drain, extended about 8 – 10” will allow the

gravity drain to empty and also keep any surges

during draining from discharging water.

Horizontal runs of drain tubing need a ¼” per fall per

foot of run for proper draining.

Follow all applicable codes.

Water Fitting

Water Supply

Connection

Water Supply

Drain Must Be

Vented

Drains Must Be

Separate

Field Supplied

Water Supply and Drain Illustration