Adjustments – Scotsman C0522R User Manual

Page 18

background image

January 2014

Page 17

C0522 through C1030

Remote Condenser Models - User Manual
Adjustments

Bridge Thickness - For the Service Tech Only

1. Push and hold Off till the machine stops.

2. Remove evaporator cover.

3. Remove curtain.

4. Use a hex wrench and rotate the bridge thickness

adjustment screw in 1/8 turn increments CW

to increase bridge thickness. Rotate CCW to

decrease bridge thickness.

Caution: Do not make the bridge too thin or the

machine will not harvest properly. Bridge thickness

adjustments are not covered by warranty.

5. Return curtain and evaporator cover to their

normal positions.

6. Push and release the On button. Check next

harvest of ice. Repeat steps 1-6 if needed.

Water Purge Setting

The water purge is factory set to automatically adjust

the amount of water purged per cycle. The setting

can be changed to one of 5 manual settings or left on

automatic.

Purge

setting

1 - Minimum 2 - Moderate

3 - Standard

4 - Heavy

5 - Maximum A - Automatic

Water

Type

RO water or

equivalent,

TDS less than

35

Low TDS non

- RO water

Setting for

typical water

High TDS

water

Very High

TDS water,

greater than

256

Factory setting,

suitable for

any water with

conductivity not

less than 10

microSiemens/cm.

To set:

1. Switch the machine OFF by holding the Off button in until a number or the letter A shows on the display.

2. Press and release the On button repeatedly until the number on the display corresponds to the desired

setting.

3. Press and release the Off switch again to return to the normal control state.

Too Big

Just Right
small cube

Just Right
med cube

Too Small

Ice Bridge Thickness Check

1/8 - 3/16 “

bridge

Bridge Thickness Adjustment Mechanism