beautypg.com

Control switches – Scotsman C0522R User Manual

Page 20

background image

January 2014

Page 19

C0522 through C1030

Remote Condenser Models - User Manual
Control Switches

The On and Off Switches are accessible from the

front of the machine.

To switch the machine OFF, push and release the Off

button. The machine will shut off at the end of the next

cycle.

To switch the machine ON, push and release the

On button. The machine will go through a start up

process and then resume ice making.

Control Options

There are two optional, field installed controls that can

be on this machine.
• VariSmart™ adjustable ice level control
• SmartBoard™ advanced control board and data

logger

Optional adjustable ice level control (KVS)

When this option is present there is an adjustment

post and an additional indicator light to the right of the

four indicator lights mentioned above. The ultrasonic

ice level control allows the user to control the point

that the ice machine will stop making ice before the

bin or dispenser is full. Reasons for this include:
• Seasonal changes in ice used
• Planning to sanitize the bin
• Faster turnover for fresher ice
• Certain dispenser applications where maximum

ice level is not desired

Use of adjustable ice level control

There are several positions the ice level can be set

to, including Off (knob and label indicators lined up),

where it fills the bin until the standard bin control shuts

the machine off. See the kit’s instructions for complete

details.

Rotate the adjustment post to the desired ice level.

The machine will fill up to that level and when it shuts

off the indicator light next to the adjustment post will

be on.

Note: Ice will build up in the bin or dispenser at an

angle, the distances listed above will be from the

sensor to the top of the ice directly beneath it.

The actual distance between the highest point of the

ice may be closer or further away, depending upon

the angle of the ice.

Adjust Ice Level

Bin

Full

No

rm L

ow

er

02-4294-01

Graphic Rev. B

Rotate knob to set ice level

Yellow Arrow = Max Ice

White Arrow = Min Ice

Left Green = Dispenser high

Norm = Lower in Dispenser

This manual is related to the following products: