Electrical

The machine is not supplied with a power cord, one

must either be field installed or the machine hard-

wired.

The dataplate on the back of the cabinet details

the power requirements, including voltage, phase,

minimum circuit ampacity and maximum fuse size.

HACR type circuit breakers may be used in place of

fuses. Extension cords are not permitted. Use of a

licensed electrician is recommended.

The ice maker is designed to operate on its own

electrical circuit and must be individually fused.

Voltage variation must not exceed the limits listed

earlier.

The remote condenser is designed to be powered

from the ice machine. A separate knockout hole has

been provided in the ice maker electrical junction box.

Electrical connections are made inside the junction

box in the back panel of the ice machine.

1. Remove the junction box cover and route the

power cord through the access hole and properly

attach the power supply wires to the leads in the

junction box.

2. Attach the remote condenser fan motor wires to

the wires in the junction box tagged “fan motor

leads”.

3. Install field supplied strain reliefs per code.

4. Attach a ground wire to the ground connection in

the junction box.

5. Check voltage when complete.

6. Return the junction box cover to its original

position and secure with the original screws.

Follow all applicable local, state and national

codes.

To Remote

Condenser

Fan Motor

Junction

Box

Cover

Power Supply

Wires

Ground Wire

Connection

Install

Strain

Relief

Install

Strain

Relief

Electrical Connection Detail