CTS-M17 Installation, Operation and Maintenance Manual

B84450-001-000 RG

May 12, 2005

15

Apply zero gas (clean air) and adjust the Zero potentiometer until the

display reading is 00.0 % (Remember that the 4-20 mA signal may be set to

a different range).

Apply an appropriate span gas (e.g. 2.5% CH4 = 50% LEL CH4), and adjust

the Gain potentiometer to get the correct reading on the display.

Press Up/Down to go to the next/previous menu item.

Remember: If the Auto-zero is enabled, you must perform the

AUTOZERO | Clear function to reset the Auto-zero

memory.

11.

Communications Protocol

P

P

R

R

O

O

T

T

O

O

C

C

O

O

L

L

O

O

p

p

t

t

o

o

m

m

u

u

x

x

The Optomux protocol (default) communicates with QEL's M-Controller.

The B4000 protocol communicates with QEL’s QDC-4000 monitor.

Press Enter and Up/Down to select the desired protocol.

12.

Digital Address

A

A

D

D

D

D

R

R

E

E

S

S

S

S

0

0

0

0

0

0

1

1

Allows changes to the digital communications address for the M-17

transmitter.

Note: The new address is available immediately after it is accepted at

this point, and the unit will respond to only this address when

queried even though you are still inside the main menu tree. If

you abort the main menu tree (see below) then the address will

revert to the previous address.

Maximum: 256

Note: If the B4000 protocol was selected (above), all

communications addresses higher than 16 will be folded back to

address 16.

13.

Baud Rate

B

B

A

A

U

U

D

D

R

R

A

A

T

T

E

E

4

4

8

8

0

0

0

0

Default is 4800 Baud.