Building type

Specific heating output in W/m

2

Passive energy house

10

Low-energy house built in 2002

40

According to energy conservation order regarding heat insulation

1995

60

Modern building constructed around 1984

80

Partially-renovated old building constructed pre-1977

100

Non-renovated old building constructed pre-1977

200

0

2

4

6

8

10

12

14

16

18

20

-15 -14 -13 -12 -11 -10 -9 -8 -7 -6 -5 -4 -3 -2 -1 0 1

2

3

4 5 6 7

8

9 10 11 12 13 14 15 16 17 18 19 20

Heat load acc.

DIN EN 12831

n.max

n-min

Min. performance

2. heat source

n.max

Heating capacity

[k

W

]

Heating capacity at a supply temperature of 35°C

Rated frequency 57 Hz

Heat load

Heat load plus warm-water

requirements and service

time-out period

Heating threshold for

old building

according to VDI 4650

Outdoor temperature [°C]

Bivalent temperature

Standard outdoor

temperature

Fig. 33: Heating capacity diagramm of the heat pump WKF/WKF-compact 180

Characteristics of REMKO inverter heat pumps

Outdoor air as a heat source

An air/water heat pump absorbs energy from the

outdoor air as its heat source and transmits this to

the heating system. They have the following

advantages over brine/water and water/water heat

pump systems:

n

Can be used everywhere Air is available every-

where in unlimited quantities. For example, no

wells are required.

n

No excavation required. No large areas are

required for soil collectors.

n

Economical. Expensive drilling is not required.

n

Excellent value for money and simple installa-

tion.

n

Particularly suitable for low-energy houses with

low inlet temperatures.

n

Ideal for bivalent operation, in order to save

energy.

REMKO WKF / WKF-compact

32

This manual is related to the following products: