The equipment is shipped in sturdy

transport packaging. Immediately

check the equipment on delivery and

make a note of any damage or miss-

ing parts on the delivery note. Inform

the forwarding agent and contractual

partner. Warranty claims at a later

date will not be accepted.

The RVD 351-1051DC room air

conditioning units have a REMKO

RVD...AT outdoor component as

well as an indoor unit RVD...IT.
The outdoor unit serves to output

the heat extracted by the indoor

unit from the room being cooled.

In heating operation, the heat

absorbed by the outdoor compo-

nent can be discharged through

the indoor unit into the room being

heated.SFlbIn both operating modes,

the performance of the compressor

precisely adjusts itself to the de-

mand, thereby regulating the target

temperature with minimal tempera-

ture variations. This "inverter-tech-

nology" enables power saving over

conventional split systems and also

reduces noise emissions to a particu-

larly low level.

The outdoor component is mounted

outdoors or under the observa-

tion of certain requirements it may

be installed indoors. The outdoor

component consists of a refrigerant

circuit with compressor, fin liquefier,

liquefier fan, reverse flow valve and

flow regulator. The outdoor unit is

controlled via the regulation of the

indoor unit.
The indoor unit is designed for
indoor installation in suspended
ceilings with Euroraster dimensions.
The cassette is hidden behind the
suspended ceiling, only its cover is
visible. Operation is undertaken via
an infrared remote control unit. The
indoor unit consists of a fin vapor-
iser, vaporiser fan, regulation system
and condensation pan.
Floor consoles, wall consoles, re-

frigerant pipes and a winter control

program are available as accessories.

Description of the
equipment

Transport and
Packaging

The connection between the indoor unit and the outdoor component is

made with refrigerant pipes.

M

M

RXT 351 DC

T2

T3

T5

RXT 521 DC

M

M

TE

P S H

T1

T2

T3

T5

P S L

M1

M3

T2

T3

T4

T5

M2

PSL

PSH

T1

M1 - Condenser fan

M2 - Compressor

M3 - Vaporiser fan IU

V1 - Reversing valve C/H

EEV - Elec. Expansion valve

PSH - High pressure switch OU

PSL - Low pressure switch OU

T1 - Sensor hot gas OU

T2 - Sensor air intake OU

T3 - Sensor condenser OU

T4 - Sensor air intake IU

T5 - Sensor vaporiser IU

Schematic of refrigerant circuit series RVD 351-1051 DC

Filter

Filter

Filter

Filter

Filter

Indoor area

Outdoor area

M1

M2

M3

T4

T2

T3

T5

T1

RXT 1051 DC

M

M

P S H

T1

T2

T3

TE

T5

P S L

T2

T3

T4

T5

M3

M2

M1

PSL

PSH

T1

Oil r

eturn

RVD 521-681 DC

RVD 1051 DC

RVD 351 DC

V1

V1

V1

EEV

EEV

IU - Indoor unit

OU - Outdoor unit

Condensate line

Condensate drain

System layout

Outdoor unit

Shut-off valve

Indoor unit

Condenser fan

Outdoor area

Injection pipe

suction pipe

Control line

Indoor area

Power output