Troubleshooting and customer service

The equipment and components are manufactured using state-of-the-art production methods and tested several times
to verify their correct function. If malfunctions should occur, please check the functions as detailed in the list below.
Please inform your dealer if the unit is still not working correctly after all the functional checks have been performed!

Malfunction

Fault

Possible cause

Checks

Remedial measures

The unit does not start
or switches itself off

Power outage, undervoltage,

defective mains fuse / main circuit

breaker switched off

Are all other

electrical installations functioning

correctly?

Check voltage

possible wait until turned on

again.

Damaged mains cable

Are all other

electrical installations functioning

correctly?

Repair by

a specialist

Waiting time after switch-on too

short

Have approx. 5 minutes

elapsed since the restart?

Schedule longer waiting

periods

Temperature outside operating

range.

Are the fans in the indoor unit

and outdoor component working

correctly?

Take into account the tempera-

ture range for the indoor unit and

outdoor component

Overvoltages caused by thunder

storms

Has there recently been lightning?

Switch off the mains breaker and

switch it back on. Have it checked

by a specialist

Fault in external condensation

pump

Did the pump shut down due to

a fault?

Check and if necessary clean the

pump

High-pressure / low-pressure
monitors have triggered

Check refrigerant pressure and

look for leaks if necessary

Rectify leakage and re-start

The unit does not respond
to the remote control

Transmission distance too far /

receiver affected by interference

Does the indoor unit beep when

pressing a button?

Reduce the distance to less than 6

m or change position

Defective remote control

Is the unit running in manual

mode?

Replace the remote control

Receiver or transmitter unit ex-

posed to excessive solar radiation

Does it function correctly in the

shade?

Place the receiver&transmitter unit

in the shade

Electromagnetic fields are interfer-

ing with transmission

Does it function when switching off

possible sources of interference?

Signal is not transmitted when in-

terference sources are operational

Button in remote control jammed

/ two buttons pressed at same

time

Does the “Send”

symbol appear on the display?

Release the button / only press

one button

Batteries in remote control are flat

Have new batteries been inserted?

Is the display incomplete?

Insert new batteries

The unit is running with
reduced or without
reduced cooling / heating
performance

Filter is unclean / air inlet / outlet

blocked by foreign items

Have the filters been cleaned?

Clean the filters

Windows and doors open. Heat-

ing/cooling output increases

Have there been any construc-

tional /

application-related

changes?

Close windows and doors / install

additional units

Neither cooling nor heating mode

has been set

Does the cooling symbol appear

on the display?

Correct the settings for the unit

Fins on outdoor component

blocked by foreign items

Is the fan on the outdoor com-

ponent running? Are the fins

unobstructed?

Check the fan or winter controller,

reduce the air resistance

Leaking refrigerant circuit

Are there signs of frost on the fins

of the indoor unit?

Repair by specialist

Outdoor component iced up

Check outdoor component. Has

the cassette sensor on the outdoor

component been correctly posi-

tioned?

De-ice and fit the sensor at the

point where the most ice forms

Condensation discharge

on unit

Drainage pipe on collection con-

tainer clogged / damaged

Can the condensation drain off

without any obstruction?

Clean the drainage pipe and col-

lection container

Faulty external condensation

pump or float

Is the collection tray full of water

and the pump not running?

Call out a specialist to replace the

pump

Condensation has not drained

away and has collected in the

condensation line

Is there a steady fall on the con-

densation pipe? Check there is no

blockage in the pipe.

Ensure there is a fall when laying

the condensation pipe and clean

the pipe.

Condensation does not drain off

Are the condensation lines un-

blocked and is there a steady fall?

Are the condensation pump and

float switch functioning correctly?

The condensation line must have

a fall. If necessary, clean the pipe.

A faulty condensation pump and

float switch should be replaced.

Float is stuck or jammed due to

excessive dirt.

Are the LEDs on the receiver unit

of the indoor unit flashing?

Should be cleaned by specialist firm