Operation, Care and maintenance, Shutdown – REMKO MVT 600 DC User Manual

Page 9

background image

Operation

Regular care, maintenance and
observation of some basic points
will ensure trouble-free operation
and a long service life.

Care and maintenance

Prior to performing any
work, ensure the equipment
is isolated from the voltage
supply and secured to prevent
accidental switch-on!

CAUTION

Temporary Shutdown

1. Allow the indoor unit to run for

2 to 3 hours in air circulation
mode or in cooling mode at the
maximum temperature setting
in order to remove any residual
moisture from the unit.

2. Shut down the system using

the remote control

3. Switch off the voltage supply

to the unit.

4. Cover as much of the unit as

possible with plastic foil to
protect it against the weather.

Permanent Shutdown

Ensure that equipment and
components are disposed of
accordance with local regulations,
e.g. through authorised disposal
and recycling specialists or at
collection points.

Contact REMKO GmbH & Co. KG
or your contract partner for local
specialist companies near you.

Shutdown

Care

Ensure the unit is protected
against dirt, mould and other
deposits.

Clean the unit using a damp
cloth.
Do not use a jet of water.

Do not use any caustic, abrasive
or solvent-based cleaning
products.

When operating the fan, clean
the fins of the unit prior to long
shutdown periods.

Maintenance

It is recommended that
maintenance contract with
annual maintenance interval
with an appropriate specialist
company.

This ensures the operational
reliability of your equipment!

TIP

The compressor in the outdoor
unit is operated by means of
regulating the control board in the
outdoor unit.

The chapter on "Regulation" in
the manual for the outdoor unit
must therefore be observed.

Type of task

Checks/Maintenance/Inspections

Commissioning

Monthly

Six-monthly

Yearly

General

Measure voltage and current

Function compressor

Check fan is functioning correctly

Dirt on liquefier

Check refrigerant fill quantity

Check condensation drain

Test insulation

Check moving parts

Sealing test for refrigerant circuit

1)

The statutory regulations
require an annual sealing
test for the refrigerant circuit
in relation to the refrigerant
filling level. The inspection
and documentation is to be
carried out by corresponding
specialist engineers.

NOTE

1) see note

9