Technical data – REMKO ATY 260 User Manual
Page 29
Technical data
Series
ATY 260
ATY 350
Operating mode
Wall / room air conditioner combination for cooling and heating
Nominal cooling output
1)
kW
2,69
3,56
Nominal heat capacity
2)
kW
3,05
3,99
Energy efficiency class Cooling EER
1)
B
B
Energy efficiency class Heating COP
2)
B
B
Energy efficiency size EER
1)
3,02
3,04
Energy efficiency size COP
2)
3,43
3,41
Operating range (room volume), approx.
m³
80
110
Refrigerant
R 410A
R 410A
Operating pressure, max. per cooling circuit
kPa
3800/1200
3800/1200
Power supply
V/Hz
230/1~/50
230/1~/50
Electr. nominal power consumption Cooling
1)
kW
0,89
1,17
Electr. nominal power consumption Heating
2)
kW
0,89
1,17
Electr. nominal current consumption Cooling
1)
A
4,10
5,60
Electr. nominal current consumption Heating
2)
A
4,00
5,40
Electr. starting current, max.
A
20
25
Refrigerant connection - injection line
Inch
(mm)
1/4 (6,35)
1/4 (6,35)
Refrigerant connection - suction line
Inch
(mm)
3/8 (9,52)
1/2 (12,7)
Associated interior unit
ATY 260 IT
ATY 350 IT
Operating range
°C
+16 to +32
+16 to +32
Adjustment range - Cooling
°C
+18 to +30
+18 to +30
Adjustment range - Heating
°C
+16 to +28
+16 to +28
Air volume per stage
m³/h
360/390/420
380/410/440
Protection type
IP
X0
X0
Sound pressure level per stage
3)
dB(A)
33/36/40
35/37/41
Dimensions Height
mm
567
567
Width
mm
567
567
Depth
mm
148
148
Weight
kg
12,0
12,0
Associated exterior unit
ATY 260 AT
ATY 350 AT
Operating range - Cooling
°C
+21 to +45
+21 to +45
Operating range - Heating
°C
-7 to +21
-7 to +21
Air volume, max.
m³/h
1340
1890
Protection type
IP
X4
X4
Sound pressure level, max.
3)
dB(A)
45
49
Refrigerant, base quantity
kg
0,63
0,83
Refrigerant, additional quantity > 5 m
g/m
10
10
Refrigerant line, length max.
m
15
15
Refrigerant line, height max.
m
5
5
Dimensions Height
mm
532
532
Width
mm
720
720
Depth
mm
245
245
Weight
kg
28,0
32,0
Serial number
740...
741...
EDV-No.
1619260
1619350
1) Air inlet temperature TK 27°C / FK 19°C, outside temperature TK 35 °C, FK 24 °C, max. air volume flow
2) Air inlet temperature TK20, outside temperature TK 7 °C / FK 6 °C, max. air volume flow
3) Distance 1 m clear field
29