Cleaning of condensation

pump (optional equipment)

An optional integrated or separate

condensation pump may be on the

interior unit, which pumps out any

accumulated condensation into

higher positioned drains.

Observe the care and maintenance

instructions in the separate

Operating instructions.

Type of work

Check / maintenance / inspection

Start up

Monthly

Semiannually

Annually

General

Check voltage and current

Check function of compressor

Check function of fan

Contamination of evaporator fins

Check refrigerant quantity

Check condensation discharge

Check insulation

Check movable parts

2 Open front cover

6 Clean with lukewarm water

2. Open the lower display cover

on the front side of the unit
by pressing both latches
and carefully fold the cover
downward and remove it from
the bracket (Fig. 3).

3. Push the clips on the filter up

and pull it out on the clips
(Fig. 4)

.

4. Clean the filter with a

commercially available vacuum
cleaner. To do so, turn the dirty
side upward (Fig. 5).

5. Carefully clean off any dirt in

lukewarm water and with mild
cleaner. To do so, turn the dirty
side downward (Fig. 6).

6. When using water, allow the

filter to air dry completely
before reinsertion into the unit.

7. Carefully reinsert the filter.

Make sure it is seated correctly.

8. Close the display cover in

reverse order as described
above.

9. Set the desired operating mode.

4 Pull out the filter

5 Clean with a vacuum cleaner

3 Remove the display cover

15