Maintenance
■
We recommend placing a
maintenance agreement with
an annual maintenance interval
with an appropriate company.
Taking the unit out of
operation
Time-limited shut down
1. Let the interior unit run for 2
to 3 hours in air circulation
mode or in cooling operation at
maximum temperature setting
to remove any residual moisture
from the unit.
2. Take the unit out of operation
with the remote control.
3. Turn the power supply of the
unit off.
4. Check the unit for visible
damage and clean it as
described in chapter „Care and
maintenance“.
Unlimited shut down
The disposal of the units and
components must be made
according to regionally valid
regulations, for example by
authorized certified disposal and
recycling companies or collection
points.
Contact REMKO GmbH & Co.
KG or your contract partner for
companies near you.
Care and maintenance
Regular care and maintenance
ensure problem-free operation and
long service life of the unit.
Care and maintenance work
may only be carried out if the
unit is disconnected.
CAUTION
Care
■
Keep the interior unit and the
exterior unit free of dirt, plant
covers and other deposits.
■
Clean the units only with a
damp cloth. Do not use harsh,
abrasive or solvent-containing
cleaners. Do not use a water
jet.
■
Before an extended shut down
period, clean the fins on the
exterior unit and cover the
exterior unit with plastic to
avoid infiltration of dirt into the
unit.
Cleaning the housing on the
interior unit
1. Disconnect the power supply to
the unit.
2. Clean the unit with a soft damp
cloth.
3. Turn the power supply on
again.
Air filter of the interior unit
Clean the air filter at intervals of
no more than 2 weeks. Reduce this
time in case of very dirty air.
Cleaning the filter on the
interior unit
The interior unit is equipped with
a filter with antibacterial coating.
The filter cleans the air of dust and
thereby reduces the distribution of
bacteria.
1. Switch the interior unit via the
remote control to air circulation
(the front cover of the air inlet
must be open!) (Fig. 2).
Before any work on the units,
the power supply must be
disconnected and secured to
prevent it from being turned
on again!
CAUTION
This ensures continuous
operating safety of the system!
NOTE
REMKO ATY