LINK SET UP
When setting up a controller as a full duplex link port, start with the following S-Command defaults:
01 1 through 3 Repeat audio path on for a full duplex repeating link
or
01 0
Repeat audio path off for a non repeating link
04 ?
Adjust repeat carrier delay as needed
34 ?
Set auxiliary output mode as required
35 ?
Set auxiliary input mode as required
36 ?
Set auxiliary input Mix/Mute mode
39 ?
Set controller address as required
REMOTE BASE SET UP
When setting up a controller as a simplex remote base port, start with the following S-Command defaults:
01 0
Repeat audio path off
04 0
No repeater carrier delay
07 0
Disable station ID
08 0
Disable courtesy message
15 ?
Disable user commands if required
32 ?
Disable any messages that you may not want to use
34 ?
Set auxiliary output mode as required
35 ?
Set auxiliary input mode as required
36 ?
Set auxiliary input Mix/Mute mode
39 ?
Set controller address as required
When changing frequencies on the remote base radio, it is best to build macros in the remote base radio that act like memory
channels. These macros should include frequency, CTCSS/DCS and any other mode changes that you need. From the repeater
controller you could then build a macro that will call the desired memory channel macro.
You can also build a user command that uses a wildcard to send direct frequency information to a remote base radio, see section
12 “Wildcard Commands”.
CONTROL RECEIVER
The RI-1 or PE-1 can be used as a control receiver to the RI-300 or another RI-1. When setting up a port as a control receiver,
you will typically disable all audio input and output, S-Command 01, 34 and 35. You would then build user commands and
macros in the control receiver port that would call macros in the main repeater port to turn on or off required features.