Pacific Research Solutions RI-1 User Manual
Page 48

Pacific Research Solutions
RI-1 and PE-1 User Manual
Page 42
S-Cmd 42 REGULAR INTERVAL EVENT
This command is used to configure a timer that will trigger a macro at a Start Line address at a regularly timed interval. There
are 2 timers available. You can use this timer to trigger a macro line that starts the ID, if you want to have a beacon ID.
SYNTAX: 42 [Timer] [Start Line] [Time]
STORAGE:
RAM/EEPROM
PARAMETERS: Timer 1–2 = Timer number
Start Line 000 = Disable this function, 001 – 255 Macro data start line.
Time 0 = Reset timer, 1–255 in 6 second increments (1 to 25.5 minutes).
DEFAULT: All timers, Start Line = 000, Time = 0.
EXAMPLE: 42 1 123 100 Timer 1 will trigger macro starting at line number 123 every 10.0 minutes.
42 2 000 0
Disable timer 2.
S-Cmd 43 RESERVED
S-Cmd 44 RESERVED