S-Cmd 45 PORT INPUT – STATE CHANGE EVENT
The controller has two digital inputs on board that can trigger macros. Each of these inputs can be configured to act on either a
negative or positive state change (falling and rising edges). When the controller detects any changes in these inputs or
functions, a macro starting at the “Macro Start Line” (1 through 255) will be executed. To disable an input or function, use 0 as
the Macro Start Line. See section 4 and 5 for information on the connector pin numbers for each input. This feature can be
used to generate an alarm message on change of an input state.
SYNTAX: 45 [Bit] [Macro start line]
STORAGE:
RAM/EEPROM
PARAMETERS: Bit 1 = Input 1 falling edge (High to Low), Bit 2 = Input 1 rising edge (Low to High)
Bit 3 = Input 2 falling edge (High to Low), Bit 4 = Input 2 rising edge (Low to High)
Macro start line 0 = Disable, 1 – 255 = Macro start lines
DEFAULT: All bits set to 0
EXAMPLE: 45 1 10
Input #1 Falling edge triggers macro starting at line 10.
45 2 11
Input #1 Rising edge triggers macro starting at line 11.
S-Cmd 46 PORT OUTPUT ON / OFF
The controller has two digital outputs on board and is expandable to 10 outputs. Each of these outputs can be directly turned on
or off with this command. See section 4 and 5 for information on the pin numbers for each output. This function can be used to
turn on something external to the controller.
SYNTAX: 46 [Output] [Mode]
READ BACK: 46 [Output]
STORAGE: RAM (Return to default at power on reset)
PARAMETERS: Output 1-1 = On board outputs
Mode 0 = off (logic low), 1 = on (logic high)
DEFAULT: All outputs are off or logic low when power is turned on
EXAMPLE: 46 1 1 Turns output number 1 on or logic high
S-Cmd 47 through 54
RESERVED
S-Cmd 55 PASSWORD FOR S-COMMAND ACCESS
The PASSWORD is used to unlock the controller for access to the S-Commands. The factory default password is 123456 and
can be changed to another set of digits from 1 to 7 digits long. When selecting a password, you should avoid using one that is
similar to a user command or the exact equivalent to an S-Command and its data. For more information on passwords, see
section 10 of this manual.
SYNTAX:
55
[Password]
STORAGE:
EEPROM
PARAMETERS: Password = 1 to 7 DTMF digits 0 through 9, *, #, A through D
DEFAULT:
123456
EXAMPLE: 55 34*685
The new password is now 34*685
55 12
The new password is now 12
S-Cmd 56 RESERVED