Dome Control Protocol Setting

Define the protocol you are going to use based on the devices of your surveillance
system. Generally, use one protocol even if the devices are provided by different
manufacturers. Use the switch to set your dome control protocol and the baud rate.
Refer to the table below and turn the arrow to choose a protocol for your speed
dome.

Protocol

Baud
Rate
Setting

Switch Setting

1

2

3

4

5

6

VCL

9600

OFF

OFF

OFF

OFF

OFF

OFF

Pelco D

2400

ON

OFF

OFF

OFF

OFF

OFF

Pelco P

4800

OFF

ON

OFF

OFF

OFF

OFF

Chiper

9600

OFF

OFF

ON

OFF

OFF

OFF

Philips

9600

ON

OFF

ON

OFF

OFF

OFF

OPTIX 3

9600

ON

ON

ON

OFF

OFF

OFF

AD422

4800

OFF

OFF

OFF

ON

OFF

OFF

DP P

9600

ON

OFF

OFF

ON

OFF

OFF

Pelco D

4800

ON

ON

OFF

ON

OFF

OFF

Pelco D

9600

OFF

OFF

ON

ON

OFF

OFF

Pelco P

2400

ON

OFF

ON

ON

OFF

OFF

Pelco P

9600

OFF

ON

ON

ON

OFF

OFF

JVC

9600

ON

ON

ON

ON

OFF

OFF

Kalatel-485

9600

ON

OFF

ON

OFF

ON

OFF

Kalatel-422

4800

OFF

ON

ON

OFF

ON

OFF

Example To set the protocol Pelco D at a 2400 baud rate, the

protocol switch should be set as shown..