beautypg.com

Nortec HumDigital User Manual

Page 16

background image

Created: 04.06.2007

16

Changed: 21.12.2007
Printed: 02.03.2009

Info for HPS 3200 (HIG)

Display

Priorit
y*

Description

Com err

1 Communication error

Cap err M

2 Capability error: CenterPur cannot fulfil the function required.

Causes: Firmware not updated, device technology outdated

Cap err D

3 Capability error: HIG cannot fulfil the function required.

Causes: Firmware not updated, device technology outdated

Motor prot. err

6 Motor protection switch (M204)

Leakage err

4 Leakage error (M201)

Min. press. err

5 Minimum pressure error (M200)

Inlet press. err

8 Inlet pressure error (M202)

Temp. err

7 Temperature error (M203)

HighPur ready

9 Container ready for operation

* When two status reports occur at once, that with lower priority is shown.

2.3 Alarms menu


Press the

“Alarms” function key to display the “Alarms” overview menu. In this

menu you can switch between the two menu levels “Pending” and “Log”.


Alarms

Pend/Hyst.

Current

"pending"

ALARMS

"Pend"

"LOG"

History

"old"

ALARMS

Detailed

ALARM

information

Detailed

ALARM

information

"DET"

"DET"

select line

Delete

"LOG" ALARMS

[only old]

"CLR"