beautypg.com

Troubleshooting – Desa VSGF36NRA User Manual

Page 28

background image

www.desatech.com

116746-01A

28

TROUBLESHOOTING

Continued

POSSIBLE CAUSE

1. Control knob not fully pressed in

2. Control knob not pressed in

long enough

3. Equipment shutoff valve not

fully open

4. Pilot flame not touching ther-

mocouple, which allows ther-

mocouple to cool, causing

pilot flame to go out. This

problem could be caused by

one or both of the following:

A) Low gas pressure

B) Dirty or partially clogged

ODS/pilot

5. Thermocouple connection

loose at control valve

6. Thermocouple damaged

7. Control valve damaged

8. Safety interlock system has

been triggered

1. Inlet gas pressure is too low

2. Burner orifice(s) clogged

3. Thermopile leads disconnect-

ed or improperly connected

4. Burner will not come on in

remote position

5. Wire disconnected from gas con-

trol (Remote ready models only)

1. Manifold pressure is too low

2. Burner orifice(s) clogged

3. Mislocated crossover tube

1. Burner orifice is clogged or

damaged

2. Damaged burner

3. Gas regulator defective

REMEDY

1. Press in control knob fully

2. After ODS/pilot lights, keep

control knob pressed in 30

seconds

3. Fully open equipment shutoff

valve

4. A) Contact local natural or

propane/LP gas company

B) Clean ODS/pilot (see

Cleaning and Maintenance,

page 25) or replace ODS/pilot

assembly

5. Hand tighten until snug, then

tighten 1/4 turn more

6. Replace pilot assembly

7. Replace control valve

8. Wait one minute for safety in-

terlock system to reset. Repeat

ignition operation.

1. Contact local natural or pro-

pane/LP gas company

2. Clean burner(s) (see Cleaning

and Maintenance, page 25)

or replace burner orifice(s)

3. Reconnect leads (see Wiring

Diagram, page 26)

4. Replace battery in transmitter

and receiver

5. See Wiring Diagram, page 26

1. Contact local natural or pro-

pane/LP gas company

2. Clean burner(s) (see Cleaning

and Maintenance, page 25) or

replace burner orifice(s)

3. Contact qualified service person

1. Clean burner (see Cleaning

and Maintenance, page 25)

or replace burner orifice(s)

2. Replace damaged burner

3. Replace gas regulator

OBSERVED PROBLEM

ODS/pilot lights but flame

goes out when control knob is

released

Burner does not light after

ODS/pilot is lit

Delayed ignition of one or both

burners

Burner backfiring during com-

bustion