beautypg.com

Installation – Desa VSGF36NRA User Manual

Page 10

background image

www.desatech.com

116746-01A

10

CAUTION: This fireplace cre-

ates warm air currents. These

currents move heat to wall sur-

faces next to fireplace. Installing

fireplace next to vinyl or cloth

wall coverings or operating

heater where impurities (such

as, but not limited, to tobacco

smoke, aromatic candles, clean-

ing fluids, oil or kerosene lamps,

etc.) in the air exist, may discolor

walls or cause odors.

Note:

Your fireplace is designed to be used in zero

clearance installations. Wall or framing material

can be placed directly against any exterior surface

on the rear, sides or top of your fireplace, except

where standoff spacers are integrally attached. If

standoff spacers are attached to your fireplace,

these spacers can be placed directly against wall

or framing materials.
Use the dimensions shown for rough openings to

create the easiest installation. See Built-In Fire-

place Installation, page 11.
IMPORTANT:

Vent-free heaters add moisture to

the air. Although this is beneficial, installing fire-

place in rooms without enough ventilation air may

cause mildew to form from too much moisture. See

Air for Combustion and Ventilation

, page 7.

IMPORTANT:

Make sure the fireplace is level.

If fireplace is not level, log set will not work

properly.
CHECK GAS TYPE
Use the correct gas type (natural or propane/LP)

for your fireplace. If your gas supply is not cor-

rect, do not install fireplace. Call dealer where you

bought fireplace for proper type fireplace.

WARNING: This appliance

is equipped for (natural or pro-

pane/LP) gas. Field conversion

is not permitted.

INSTALLATION

Continued

INSTALLATION CLEARANCES

WARNING: Maintain the

minimum clearances. If you

can, provide greater clearances

from floor, ceiling and adjoining

wall.

Carefully follow the instructions below. This will

ensure safe installation.
Minimum Wall and Ceiling Clearances (see
Figure 6)
A. Clearances from the side of the fireplace

cabinet to any combustible material and wall

should follow diagram in Figure 6.

Example:

The face of a mantel, bookshelf,

etc. is made of combustible material and

protrudes 3

1

/

2

" from the wall. This combus-

tible material must be 4" from the side of the

fireplace cabinet (see Figure 6).

B. Clearances from the top of the firebox open-

ing to the ceiling should not be less than 42

inches.

C. When the firebox is installed on carpeting or

other combustible material, other than wood

flooring, the firebox should be installed on a

metal or wood panel extending the full width

and depth of the enclosure.

D. Clearances from the bottom of firebox to the

floor is 0 inches.

These fireboxes can be installed as freestanding

units against a wall with the approved, optional

cabinet mantels (see Accessories, page 31) or as a

built-in unit. The clearances are the same for either

installation method.

CAUTION: Do not install the

firebox directly on carpet or

vinyl.

*Minimum 16 inches from Side Wall

*

Example

Figure 6 - Minimum Clearance for

Combustible to Wall

This manual is related to the following products: