beautypg.com

Installation – Desa VSGF36NRA User Manual

Page 15

background image

www.desatech.com

116746-01A

15

Note:

If adding the G8007 series brick liner acces-

sory, install it now. Follow instructions in G8007

accessory kit.

CAUTION: Do not pick up

log base assembly by burner.

This could damage burner. Only

handle base by grates.

3. Route gas line (provided by installer) from

equipment shutoff valve to fireplace. Route

flexible gas supply line through one of the

access holes.

NOTICE: Most building codes

do not permit concealed gas

connections. A flexible gas line

is provided to allow accessibility

from the fireplace (see Figure 17).

The flexible gas supply line con-

nection to the equipment shutoff

valve should be accessible.

4. Attach the flexible gas line to gas supply (see

Figure 17). Check tightness of flexible gas

line attached to gas regulator of fireplace (see

Figure 17).

5. Check all gas connections for leaks. See

Checking Gas Connections, page 16.

6. Replace log base assembly back into fireplace.

Feed flexible gas line into fireplace base area

while replacing log base assembly. Make sure

the entire flexible gas line is in fireplace base

area. Reattach log base assembly to fireplace

with screws removed in step 2.

INSTALLATION

Continued

Figure 16 - Removing Log Base

Assembly From Fireplace

Figure 17 - Attaching Flexible Gas Lines

Together

Flexible Gas Line
from Fireplace
Gas Regulator

To Fireplace
Gas Regulator

Equipment
Shutoff Valve
Provided by
Installer

Propane/LP
To External
Regulator

Natural Gas
To Gas Meter

WARNING: Use pipe joint

sealant that is resistant to liquid

petroleum (LP) gas.

We recommend that you install a sediment trap in

supply line as shown in Figure 15, page 14. Locate

sediment trap where it is within reach for clean-

ing. Install in piping system between fuel supply

and fireplace. Locate sediment trap where trapped

matter is not likely to freeze. A sediment trap traps

moisture and contaminants. This keeps them from

going into fireplace gas controls. If sediment trap

is not installed or is installed wrong, fireplace may

not run properly.

CONNECTING FIREPLACE TO GAS
SUPPLY

Installation Items Needed
• 5/16" hex socket wrench or nut-driver
• Phillips screwdriver
• sealant (resistant to propane/LP gas, not pro-

vided)

1. Remove fireplace screen. Remove one screw

that holds fireplace screen in place for ship-

ping. This screw is located near top left side

of screen. Discard screw. Lift fireplace screen

up and pull out to remove.

2. Remove screws that attach log base assembly

to fireplace (see Figure 16). Carefully lift up

log base assembly and remove from fireplace

(see Figure 16).

This manual is related to the following products: