Operation - model md44-dv, For your safety - read before lighting, Lighting instructions – Montigo MD44 DV User Manual
Page 13: With continuous pilot

Page 13
Part No. XG0120
MD44-DV Direct Vent Vented Fireplace
For Your Safety - READ BEFORE LIGHTING:
WARNING:
If you do not follow these instructions exactly, a fire or explosion
may result causing property damage, personal injury or loss of life.
n
If you cannot reach your gas supplier, call the Fire
Department.
C. Use only your hand to push in or turn the gas control
knob. Never use tools. If the knob will not push in or
turn by hand, don't try to repair it, call a qualified
service technician. Force or attempt to repair may
result in a fire or explosion.
D. Do not use this appliance if any part has been under
water. Immediately call a qualified service technician
to inspect the appliance and to replace any part of the
control system, and any gas control which has been
under water.
A.
This appliance has a pilot which must be lighted by
hand. When lighting the pilot, follow these instructions
exactly.
B. BEFORE LIGHTING smell all around the appliance
area for gas. Be sure to smell next to the floor
because some gas is heavier than air and will settle
on the floor.
What To Do If You Smell Gas:
n
Do not try to light any appliance.
n
Do not touch any electrical switch; do not use any
phone in your building.
n
Immediately call your gas supplier from a
neighbour's phone. Follow the gas supplier's
instructions.
To Turn Off Gas To Appliance:
Operation - Model MD44-DV
3. Push in gas control knob slightly and turn
clockwise to "Off". Do not force.
4. Flip up horizontal trim.
1. Turn off remote switch.
2. Fip down lower horizontal trim.
1.
STOP! Read the safety information above on this
label.
2. Flip down lower horizontal trims.
3. Push in gas control knob and turn clockwise
to
"OFF."
4. Wait five (5) minutes to clear out any gas. Smell for
gas, including near the floor. If you then smell gas,
STOP! Follow "B" in the safety information above on
this label. If you don't smell gas, go to the next step.
5. Locate pilot burner (See illustration at right.) and follow
steps below.
6. Turn knob on gas control counterclockwise
to
"PILOT."
7. Push in gas control knob completely and hold. Light
with Piezo Igniter button. Continue to hold the control
knob in for about (1) minute after the pilot is lit. Release
the knob and it will pop back up. Pilot should remain lit.
If it goes out repeat steps 3 through 8.
n
If knob does not pop up when released. Stop and
immediately call your
service technician or gas
supplier.
n
If the pilot will not stay lit
after several tries, turn the
gas control knob to "OFF"
and call your service techni-
cian or gas supplier.
8. Push in gas control knob and
turn counterclockwise
to "ON."
9. Flip up lower horizontal trims.
10.Turn on remote switch to ignite fire.
Lighting Instructions:
Gas Control Knob
(Shown in "Pilot" postion.)
NOTE: Knob cannot be turned from
"PILOT" to "OFF" unless knob is
pushed in slightly. Do not force.
MD44-DV
with Continuous Pilot