Installation
Section 8: Installing & Removing the Door
Removing the door:
The H*42DF* doors are removed in a few simple steps. Follow these
instructions below to remove the Horizontal access panel, unlatch the
door buckles and, remove the door. Replace in reverse order.
Figure 26a. Locate the door buckles.
Figure 26. Removing and installing the Horizontal Access Panel
Locate the Door Buckles:
Step 2:
Step 1:
Remove the Horizontal cover
by placing fingers in both finger
holes, then pushing away from
you and lifting out. Place it
aside during maintenance or
cleaning.
Install in reverse order.
Remove the Horizontal Access Panel:
2
Step 5:
Ensure the tool is firmly
in the lower end of the
slot, (as shown), Then pull
toward you (Caution: hold
the tool securely).
3
Step 6:
Pull hard if necessary to
release the spring ten-
sion. (Caution: The latch
springs back with force,
hold the tool securely).
4
Step 7:
Remove the tool from
the latch slot. Ensure the
latches are hanging freely,
the hook end is released
from the bottom of the door.
(Repeat all 4-steps for the
remaining latches).
Figure 26d.
Figure 26e.
Figure 26f.
Figure 21a. Locate the door buckles. (Both Sides Typical)
Door Latch Hook
Door Latch Slot
Hand-hold
Release the Door Buckles
Figure 26b. Door buckle Tool
1
Step 4:
Firmly grasp hand-hold
end of Door buckle tool
and place the machined
end in the slot under door
frame. (as shown)
Figure 26c.
Step 3:
Finger Holes
Installed Gas
Valve Cover
WARNING
When reinstalling door(s), always make sure all door
buckles are properly hooked and fully engaged.