Section 3-3-1: venting layout, Installation – Montigo H42DF User Manual
Page 12

H*42DF Indoor Gas Fireplace
Page 12
XG0148 - 150204.1
Installation
The Venting Graph: H*42DF*
Measure the vertical height from the fireplace hearth to the centre of the
termination and the horizontal run from the fireplace flue collar to the wall
flange of the termination. Plot on the Venting Graph Figure 13 with an 'X'.
If the 'X' falls on or above the top boundary of the shaded area, the
installation is acceptable.
Example A: (Acceptable Installation)
If the vertical dimension from the hearth is 84" and the horizontal run to
the wall flange of the vent termination is 36", this would be an acceptable
installation.
Example B: (Acceptable Installation)
If the vertical dimension from the hearth is 72" and the horizontal run to
the wall flange of the vent termination is 66", this would be an acceptable
installation.
Example C: (Unacceptable Installation)
If the vertical dimension from the floor of the fireplace is 72" and the
horizontal run to the wall flange of the vent termination is 108", this would
NOT be an acceptable installation.
Figure 13. H*42DF* Top Vent Venting Graph for wall mounted terminations.
Section 3-3-1:
Venting Layout:
Wall mounted termination. Selection of components and details
of venting layout should adhere to the following guidelines:
Vent terminations must not be recessed in walls or siding.
For Heat Shield requirements see Section 3-3-3.
Once the proposed venting layout has been determined refer
to Figure 13 or 15 to ensure the layout is acceptable.
Notes Wall Mounted Terminations: TOP VENT
All measurements for vertical or horizontal runs are measured
from center of the vent pipe.
Venting runs must fall within the limits set by the venting graph,
see Figure 13.
Wall mounted Terminations
The following details are some possible configurations for Wall
mounted terminations.
Figure 13a. Top Vented, wall mounted installation with one 90° bend. The vent
run must comply with Venting Graph for Top vent, wall mounted terminations,
Figure 13.
Figure 13b. Top Vented, wall mounted Multi-elbow installation. See Venting
Graph for Top vent, wall mounted terminations, Figure 13.
42”
46”
B
C
A
Ve
rtical Run (in.)
Unacceptable vent run
within shaded area.
Acceptable vent run
within non-shaded area.
If your installation does not fall
within the venting graph parameters,
please contact a local Montigo
dealer for Power Venting options.
Solid Section
Flex Section
Hearth
15’foot Max.
Heat
Shield
Termination
Exterior
Wall
Heat
Shield
Termination
Hearth
Exterior
Wall
46”Min.
42” Max.
Flex or Ridig
section