Installation – Montigo H42DF User Manual
Page 15

H*42DF Indoor Gas Fireplace
Page 15
XG0148 - 150204.1
Installation
Figure 14. Corner installation. (NG Models Only)
Figure 14a. Flex installation. (NG Models Only)
45° Corner Installation.
Attach an PEL-45 (45° elbow) directly onto the flue collar. Cut the
PXT-20 to suit, and attach it to the PEL-45. Slide the fireplace into
position and attach to the termination.
45° or less Corner Installation.
Use an PTO-3 termination and an PFL-1 or PFL-2/PFL-2 (12" or 24"
compressed length) and a frame, if appropriate. Flex may be turned
to obtain desired degree of angle required but must not exceed 45°.
Note: Through the wall venting kits are also available for both
the Straight and the Corner Installation. The Kit includes a heat
shield, a PFL-12 (f/f) flexible pipe, and a termination with or without
a mounting frame.
PEL-45 Elbow
PEL-90 Elbow
PXT-18
Heat Shield
Heat Shield