Side wall clearances are 3". Combustible surrounds may be installed with
3" clearance to the side of the fireplace as shown in Figure 26 or 26a.
Figure 26. H34DF* and HL34DF*Combustible surrounds.
Mantels & Surrounds
NOTE: National Canadian Gas Association mantel test requirements
are for fire hazard prevention to combustible materials.
New technology, to meet consumer and government demands for the
wise use of energy, has prompted us to manufacture many models of
fireplaces which are hot, fuel and energy efficient.
Please be aware; temperatures over the mantel will rise above normal
room temperature and walls above fireplace may be hot to touch.
Figure 26a. HC34DF* Combustible surrounds.
Combustible Header
Drywall/
Sheetrock
3”
45°
6”
Combustible Header
Drywall/ Sheetrock
3”
45°
6”
3”
Nailing Flange
WARNING
Do not place any materials or objects on top of the
valve blind. Doing so could result in failure of door
relief system or heat dissipation.