6. Maintenance

6-5

Symptom Cause

Countermeasures

It is indicated that engine

oil pressure is abnormal,
and engine stops.

(1) Engine oil shortage.

(2) Engine oil filter clogging.

(3) Faulty oil pressure switch.
(4) Loosened or disconnected

wiring or connector.

Replenish oil

Change

Change
Check/Fasten

It is indicated that coolant

temperature is abnormal,
and engine stops.

(1) Radiator clogging.

(2) Faulty thermostat.
(3) Faulty coolant temp. switch.

(4) Low coolant level.

(5) Fan belt slippage.
(6) Loose wiring, connectors and

disconnection.

(7) Coolant temp. sensor is

disconnected.

Clean

Change
Change

Replenish

Re-adjust tension
Check/retighten

Repair and replace

It is indicated that
discharge air temperature

is abnormal, and engine

stops.

(1) Oil cooler clogging.
(2) Oil filter clogging.

(3) Faulty discharged air temp.

switch.

(4) Loose wiring connectors and

disconnection.

(5) Slippage of fan belt.
(6) Shortage of compressor oil.

(7) Discharge air temp. sensor is

disconnected.

Clean
Change

Disassemble/Check


Check/retighten

Re-adjust tension
Replenish oil

Repair and replace



Contact your nearest dealer if you find it difficult to repair by yourselves.



Refer to the engine operation manual for trouble concerning the engine.

6.4 Adjustment of Various data



The following set values can be altered and adjusted.

No.

Item

Indication

Unit

Primary set value

Pange of set values

1 Purge releasing pressure

PSI

86

70~100

2

Waiting time for

transfer to purge

mode operation

Second

10

5~60

3

Load factor for

transfer to purge

mode operation

15

5~30





When auto-idle switch is pressed longer (than 5 second), first L. (Purge releasing pressure) is

displayed. Each time auto-idle switch is pressed, each indication will be selected. Then each

time it is pressed one time, T. (Waiting time for transfer to purge mode operation) is switched

to b. (Load factor for transfer to purge mode operation),according to the set orders.




[Purge releasing pressure]

[Waiting time for transfer

to purge mode operation

]

[Load factor for transfer

to purge mode operation]

Press three

times after

setting job

is finished.

UP

DOWN

UP

DOWN

UP

DOWN

Press two

times after

setting job

is finished.

<Procedures of adjustment>

Press one

time after

setting job

is finished.