4.Operation
4-11
4.4.4 Gauge Indication while operating
Minimum discharge air pressure is 58psi (4bar) during operation.
Continuing equipment operation at a lower pressure than the above pressure may cause overheating,
since it affects the separation of lubricating oil inside the oil separator and reduces the oil flow to the
compressor air-end, resulting in temperature rise.
Be sure to check at times to see if gauges or each component of the unit are properly working, or if
there is any air-leak, oil-leak, water-leak or fuel-leak etc.
During normal operation, each indication of instruments is shown in the table below. Refer to the
table for daily checks.
The above table gives standard values. They may vary slightly depending on the operating
conditions and other factors.
Indicator lamp
Protection
device
GLOW CHARGE
Auto
idle
Monitor
AUTO IDLE
Starting
Starter
switch set
to “RUN”
position
OFF
※
0N
OFF
In operation
OFF
※
This lamp will be OFF in 0 to 20 seconds, (varying upon ambient temperature.)
Discharge
pressure gauge
Full load
58 to 100 psi
(4 to 6.9 bar)
No load
(Unload)
104 to 131 psi
(7.2 to 9.0 bar)
In op
erat
io
n
At purge control
(AUTO IDLE)
58 to 73 psi
(4.0 to 5.0 bar)