5.Periodic Inspection/Maintenance

5-10

5.5.9 Clean of element in sedimenter

[Every 500 hours]

Turn fuel selector valve“1”to“OFF”position.

Loosen the drain valve“2”and drain out condensed

water inside.

Turn the cup“3”to the left and remove it.

Be careful to remove the cup“3”because it is filled
with fuel. Wipe out split fuel completely.

Remove float“4”inside cup“3”.

Washing element“5”and the cup inside with new

fuel.

Replace element“5”and o-ring“6”,“7”if they are

found broken or damaged. (For part number, see 5.4)

After finishing clean, assemble it in reverse

procedure.



If air is found still in fuel pipe, place starter switch

to“RUN”position and loosen air bleeding bolt“8”
to bleed air. After finishing air bleeding, tighten the
air bleeding bolt“8”.



Drain the condensate in container“9”,and then

dispose of condensate according to the designated
regulations.

5.5.10 Change fuel filter

[Every 500 hours]

Remove the fuel filter cartridge“1”, using a filter wrench.

Install the new cartridge“1”after applying oil to the

surface of gasket“2”of cartridge“1”.
(For part number, see 5.4)

Give 1 turn to the cartridge“1”by hand after the packing

touches the sealing face.

After installing fuel filter cartridge“1”, check for fuel leak

during operation.


A100117

1 8

7
6

5

3

4

2

9

ON

OFF

H000049

1

2