Periodic inspection/maintenance – MMD Equipment 185S-6C2 User Manual
Page 43

5.Periodic Inspection/Maintenance
5-10
5.5.9 Clean of element in sedimenter
[Every 500 hours]
①
Turn fuel selector valve“1”to“OFF”position.
②
Loosen the drain valve“2”and drain out condensed
water inside.
③
Turn the cup“3”to the left and remove it.
Be careful to remove the cup“3”because it is filled
with fuel. Wipe out split fuel completely.
④
Remove float“4”inside cup“3”.
⑤
Washing element“5”and the cup inside with new
fuel.
⑥
Replace element“5”and o-ring“6”,“7”if they are
found broken or damaged. (For part number, see 5.4)
⑦
After finishing clean, assemble it in reverse
procedure.
If air is found still in fuel pipe, place starter switch
to“RUN”position and loosen air bleeding bolt“8”
to bleed air. After finishing air bleeding, tighten the
air bleeding bolt“8”.
Drain the condensate in container“9”,and then
dispose of condensate according to the designated
regulations.
5.5.10 Change fuel filter
[Every 500 hours]
①
Remove the fuel filter cartridge“1”, using a filter wrench.
②
Install the new cartridge“1”after applying oil to the
surface of gasket“2”of cartridge“1”.
(For part number, see 5.4)
③
Give 1 turn to the cartridge“1”by hand after the packing
touches the sealing face.
④
After installing fuel filter cartridge“1”, check for fuel leak
during operation.
A100117
1 8
7
6
5
3
4
2
9
ON
OFF
H000049
1
2