5.Periodic Inspection/Maintenance
5-15
5.5.21 Change o-ring of unloader
[3,000 hours or every 3 years]
Supply grease to O-ring“1”,“2”,“3”,“4”after replacement.
(For part number, see 5.4)
Grease: CALTEX MULTIFAX EP1
5.5.22 Check rubber hose
[3,000 hours or every 3 years]
Check hoses used for oil piping for any crack or tear, and replace when an abnormality is found.
When replacing hoses, contact directly us or distributor because it requires expert technical
knowledge.
5.5.23 Change radiator hoses
[3,000 hours or every 3 years ]
When any crack or wear is found on the hoses, change it even before the scheduled time.
When replacing it, contact directly us or distributor because it requires expert technical knowledge.
A070337
1
2
4
3
1