CobraMig 260 Owner's Manual - Page 30

FLOW CHART

PROBLEM AREA

POWER SUPPLY CONTROL BOARD, K2 RELAY MAIN BOARD, TRIAC

SYMPTOM

CONTACTOR CLOSED, WIRE ALWAYS ENERGIZED

11

START

YES

NO

YES

NO

NO

YES

PSCB IS DEFECTIVE

TRANSFORMER

RELAY IS

DEFECTIVE OR NO

AC INPUT, CHECK

DISCONNECT FUSE

REMOVE JUMPER

FROM TP1:TP5

DISCONNECT J6 ON PSCB

YES

NO

YES

NO

PSCB IS DEFECTIVE

CLOSED SIGNAL

YES

NO

RESEAT K2 RELAY

REPLACE IF

NECESSARY

YES

NO

11

IS PSCB LED D7 ON?

JUMP TP1 TO TP5

IS PSCB LED D12 ON?

IS PSCB FUSE F1 OK?

PSCB IS DEFECTIVE

CONTACTOR STILL CLOSED?

IS THE WELDING

VOLTAGE

CONTROLLABLE?

DISCONNECT J5

ON THE PSCB

USING OHMMETER,

CHECK FOR

CONTINUITY ACROSS

J6-3 AND J6-4 ON

MAIN PC BOARD

PSCB IS DEFECTIVE

IS THE WELDING

WIRE STILL

ENERGIZED?

REPLACE TRIAC

PSCB IS DEFECTIVE