CobraMig 260 Owner's Manual - Page 27

FLOW CHART

NO

CAPACITORS SHORTED

YES

PROBLEM AREA

POWER TRANSFORMER "T1", DIODES, CAPACITORS

SYMPTOM

DISCONNECT FUSE BLOWS WHEN TORCH IS TRIGGERED

START

USING AN OHM METER, MEASURE THE RESISTANCE AT J6-1

(WELD VOLTS) AND J6-2 (WORK GROUND) ON COBRA I MAIN

BOARD, READING SHOULD BE APPROX. 25 OHM

TURN OFF ALL POWER

AND DISCONNECTS

NO

YES

IS READING OK ?

POWER TRANSFORMER "T1"

IS DEFECTIVE

DISCONNECT DIODES FROM
POWER TRANSFORMER T1 :
ANODE D1 FROM T1-6
ANODE D2 FROM T1-5

IS READING AT J6-1 AND J6-2

APPROX. 25 OHM NOW ?

NO

YES

8

8

DIODE IS OK

DIODE IS DEFECTIVE

IS READING OK ?

SET OHM METER ON DIODE CHECK MODE
MEASURE DIODE RESISTANCE :
PLACE (+) LEAD ON ANODE AND (-) LEAD ON HEATSINK
READING SHOULD BE APPROX. 300 TO 800 OHMS
PLACE (-) LEAD ON ANODE AND (+) LEAD ON HEATSINK
READING SHOULD BE OPEN.