beautypg.com

Flow chart – MK Products CobraMig 260 PS/Feeder User Manual

Page 29

background image

CobraMig 260 Owner's Manual - Page 23

FLOW CHART

NOTE :
When the Cobra I front panel power switch is on, 115VAC is sent to the coil of Transformer Relay
and 27 VAC is sent to Cobra I main board. When the torch is triggered, then K2 on Cobra I main
board is energized. This action transfer 115 VAC to the slave motor, brake solenoid and controlled
voltage to the torch motor.

TRANSFORMER RELAY VOLTAGES : When torch trigger is depressed
115 VAC COM (White), Pin A to 115 VAC HOT (Neu), Pin B = 115 VAC
27 VAC COM (Brown), Pin 7 to 27 VAC HOT (Orange), Pin 9 = 27 VAC
27 VAC COM (Yellow), Pin 4 to 27 VAC HOT (Blue), Pin 6 = 27 VAC

4

4

SYMPTOM

COBRA MAIN BOARD, F1 AND F3 FUSES ARE OK

BUT NO WIRE FEED AT TORCH AND FEEDER NOT OPERATING

PROBLEM AREA

K2 RELAY ON COBRA I MAIN BOARD,

TRANSFORMER RELAY OR TORCH MOUNTED MICRO SWITCH

NO

GO TO FLOW CHART #3
COBRA I MAIN BOARD,
F1 FUSE IS BLOWN

YES

TRANSFORMER RELAY IS

DEFECTIVE OR CABLE

ASSEMBLY MISWIRED (SEE

NOTE)

IS THE COBRA FRONT

L.E.D. POWER LIGHT ON ?

NO

YES

UNPLUG TORCH AMPHENOL

FROM COBRA FRONT PANEL

COBRA I MAIN P.C. BOARD, K2 RELAY

IS INOPERATIVE OR LOOSE J2, J3

CONNECTORS ON MAIN BOARD

MICRO SWITCH IS DEFECTIVE

START

IS COBRA MAIN

BOARD F1 FUSE OK?

NO

YES

JUMPER "E" AND "F" ON EITHER

OF THE COBRA FRONT PANEL

AMPHENOL CONNECTORS

IS WIRE FEEDING OK ?