beautypg.com

Flow chart – MK Products CobraMig 260 PS/Feeder User Manual

Page 34

background image

CobraMig 260 Owner's Manual - Page 28

FLOW CHART

PROBLEM AREA

CURRENT SENSOR, COBRA I MAIN BOARD, READ POSA START SECTION.

SYMPTOM

POSA START NO WORKING PROPERLY

9

9

NO

YES

PLUG IN J2
REMOVE J1 ON COBRA I MAIN BOARD.
USING OHM METER MEASURE RESISTANCE OF
CURRENT SENSOR
THE READING SHOULD BE OPEN

NO

CURRENT SENSOR IS DEFECTIVE

(CLOSED ALL THE TIME)

YES

IS READING OK ?

TO CHECK POSA START POT :
REMOVE J2 ON COBRA I MAIN BOARD, TURN ON POSA START SWITCH
USING OHM METER METER RESISTANCE AT J2-1 AND J2-2 RIBBON CABLE
READING SHOULD VARY FROM 0 TO 100K OHM

NO

YES

JUMPER J1-1 AND J1-2 ON COBRA 1 MAIN BOARD

DOES TORCH MOTOR SPEED

INCREASE WHEN JUMPER IS

ADDED?

POSA START POT OR
POSA START SWITCH DEFECTIVE

USING A VOLT METER, MEASURE THE WELD VOLTAGE
AT J6-2(-) AND J6-1(+) ON COBRA I MAIN BOARD
SET POSA POT = 1/4 TURN ON
SET TORCH POT = MAXIMUM (CW)
TURN ON COBRAMIG 260
TRIGGER AND ADJUST WELD VOLTS TO APPROX 15V

COBRA I MAIN BOARD

IS DEFECTIVE

CURRENT SENSOR IS DEFECTIVE

(OPEN ALL THE TIME)

IS READING OK ?

START