Technical data

Blind zone

Operating range
Maximum range

Angle of beam spread

20 mm
150 mm

55 mm
240 mm

250 mm
See detection zone

350 mm
See detection zone

Transducer frequency

Resolution, sampling rate

Reproducibility

Detection zones

for different objects:

The dark grey areas are determined

with a thin round bar (10 mm dia.)

and indicate the typical operating range

of a sensor. In order to obtain the light grey

areas, a plate (100 x 100 mm) is introduced

into the beam spread from the side.

In doing so, the optimum angle between

plate and sensor is always employed.

This therefore indicates the maximum

detection zone of the sensor.

It is not possible to evaluate ultrasonic

reflections outside this area.

380 kHz
0,20 mm

500 kHz
0,20 mm

± 0,15 %

± 0,15 %

Accuracy

Operating voltage U

B

Voltage ripple

No-load current consumption

Temperature drift internal compensated,

≤ 2 %

20 – 30 V DC, reverse polarity protection

Temperature drift internal compensated,

≤ 2 %

20 – 30 V DC, reverse polarity protection

±10 %
< 25 mA

±10 %
< 35 mA

Housing

Class of protection to EN 60 529

ABS
ultrasonic transducer: polyurethane foam,

ABS
ultrasonic transducer: polyurethane foam,

epoxy resin with glass content
IP 67

epoxy resin with glass content
IP 67

Type of connection

Controls

Indicators

4-pin M8 initiator plug
Yes, Teach-in push-button

4-pin M8 initiator plug
Yes, Teach-in push-button

LED green (operation)
LED yellow (state of output)

LED green (operation)
LED yellow (state of output)

Programmable

Synchronisation

Pulse width synchroniszation signal t

i

Repetition rate synchronization signal t

p

No
Yes, external

No
Yes, external

> 150 µs
8 ms < t

p

< 1 s

> 150 µs
10 ms < t

p

< 1 s

Operating temperature

Storage temperature

Weight

Response time

-25°C to +70°C
-40°C to +85°C

-25°C to +70°C
-40°C to +85°C

10 g
50 ms

10 g
50 ms

Time delay before availability

Norm conformity

Order no.

< 300 ms
EN 60947-5-2

< 300 ms
EN 60947-5-2

zws-15/CI/QS

zws-24/CI/QS

Analogue output 4 - 20 mA

Order no.

R

L

≤ 500 Ω

rising/falling characteristic

R

L

≤ 500 Ω

rising/falling characteristic

zws-15/CU/QS

zws-24/CU/QS

Analogue output 0 - 10 V R

L

≥ 100 kΩ , short-circuit-proof,

rising/falling characteristic

R

L

≥ 100 kΩ , short-circuit-proof,

rising/falling characteristic

120 mm
700 mm
1000 mm
See detection zone
300 kHz
0,20 mm
± 0,15 %

Temperature drift internal compensated,

≤ 2 %

20 – 30 V DC, reverse polarity protection
±10 %
< 35 mA
ABS
ultrasonic transducer: polyurethane foam,
epoxy resin with glass content
IP 67
4-pin M8 initiator plug
Yes, Teach-in push-button
LED green (operation)
LED yellow (state of output)
No
Yes, external
> 150 µs
14 ms < t

p

< 1 s

-25°C to +70°C
-40°C to +85°C
11 g
70 ms
< 300 ms
EN 60947-5-2

zws-70/CI/QS
R

L

≤ 500 Ω

rising/falling characteristic

zws-70/CU/QS
R

L

≥ 100 kΩ , short-circuit-proof,

rising/falling characteristic

1 analogue output

1

2

4

3

+U

B

-U

B

Sync

U

R

L

I | U

zws-15...

zws-24...

8 cm

4 cm

0 cm

4 cm

8 cm

0 cm

4 cm

8 cm

12 cm

16 cm

20 cm

24 cm

Round bar ø 10 mm

Plate

10 cm

5 cm

0 cm

5 cm

10 cm

0 cm

5 cm

10 cm

15 cm

20 cm

25 cm

30 cm

35 cm

40 cm

Plate

Round bar ø 10 mm

zws-70...

40 cm

20 cm

0 cm

20 cm

40 cm

0 cm

20 cm

40 cm

60 cm

80 cm

100 cm

Round bar ø 10 mm

Plate

microsonic GmbH • Hauert 16 • D-44227 Dortmund • Tel: +49 2 31 / 97 51 51-0 • Fax: +49 2 31 / 97 51 51-51 • E-Mail: [email protected] • www.microsonic.de
The content of this document is subject to technical changes. Specifications in this document are presented in a descriptive way only. They do not warrant any product features.

*B6285*