Technical data
Blind zone
Operating range
Maximum range
Angle of beam spread
20 mm
150 mm
55 mm
240 mm
250 mm
See detection zone
350 mm
See detection zone
Transducer frequency
Resolution, sampling rate
Reproducibility
Detection zones
for different objects:
The dark grey areas are determined
with a thin round bar (10 mm dia.)
and indicate the typical operating range
of a sensor. In order to obtain the light grey
areas, a plate (100 x 100 mm) is introduced
into the beam spread from the side.
In doing so, the optimum angle between
plate and sensor is always employed.
This therefore indicates the maximum
detection zone of the sensor.
It is not possible to evaluate ultrasonic
reflections outside this area.
380 kHz
0,20 mm
500 kHz
0,20 mm
± 0,15 %
± 0,15 %
Accuracy
Operating voltage U
B
Voltage ripple
No-load current consumption
Temperature drift internal compensated,
≤ 2 %
20 – 30 V DC, reverse polarity protection
Temperature drift internal compensated,
≤ 2 %
20 – 30 V DC, reverse polarity protection
±10 %
< 25 mA
±10 %
< 35 mA
Housing
Class of protection to EN 60 529
ABS
ultrasonic transducer: polyurethane foam,
ABS
ultrasonic transducer: polyurethane foam,
epoxy resin with glass content
IP 67
epoxy resin with glass content
IP 67
Type of connection
Controls
Indicators
4-pin M8 initiator plug
Yes, Teach-in push-button
4-pin M8 initiator plug
Yes, Teach-in push-button
LED green (operation)
LED yellow (state of output)
LED green (operation)
LED yellow (state of output)
Programmable
Synchronisation
Pulse width synchroniszation signal t
i
Repetition rate synchronization signal t
p
No
Yes, external
No
Yes, external
> 150 µs
8 ms < t
p
< 1 s
> 150 µs
10 ms < t
p
< 1 s
Operating temperature
Storage temperature
Weight
Response time
-25°C to +70°C
-40°C to +85°C
-25°C to +70°C
-40°C to +85°C
10 g
50 ms
10 g
50 ms
Time delay before availability
Norm conformity
Order no.
< 300 ms
EN 60947-5-2
< 300 ms
EN 60947-5-2
zws-15/CI/QS
zws-24/CI/QS
Analogue output 4 - 20 mA
Order no.
R
L
≤ 500 Ω
rising/falling characteristic
R
L
≤ 500 Ω
rising/falling characteristic
zws-15/CU/QS
zws-24/CU/QS
Analogue output 0 - 10 V R
L
≥ 100 kΩ , short-circuit-proof,
rising/falling characteristic
R
L
≥ 100 kΩ , short-circuit-proof,
rising/falling characteristic
120 mm
700 mm
1000 mm
See detection zone
300 kHz
0,20 mm
± 0,15 %
Temperature drift internal compensated,
≤ 2 %
20 – 30 V DC, reverse polarity protection
±10 %
< 35 mA
ABS
ultrasonic transducer: polyurethane foam,
epoxy resin with glass content
IP 67
4-pin M8 initiator plug
Yes, Teach-in push-button
LED green (operation)
LED yellow (state of output)
No
Yes, external
> 150 µs
14 ms < t
p
< 1 s
-25°C to +70°C
-40°C to +85°C
11 g
70 ms
< 300 ms
EN 60947-5-2
zws-70/CI/QS
R
L
≤ 500 Ω
rising/falling characteristic
zws-70/CU/QS
R
L
≥ 100 kΩ , short-circuit-proof,
rising/falling characteristic
1 analogue output
1
2
4
3
+U
B
-U
B
Sync
U
R
L
I | U
zws-15...
zws-24...
8 cm
4 cm
0 cm
4 cm
8 cm
0 cm
4 cm
8 cm
12 cm
16 cm
20 cm
24 cm
Round bar ø 10 mm
Plate
10 cm
5 cm
0 cm
5 cm
10 cm
0 cm
5 cm
10 cm
15 cm
20 cm
25 cm
30 cm
35 cm
40 cm
Plate
Round bar ø 10 mm
zws-70...
40 cm
20 cm
0 cm
20 cm
40 cm
0 cm
20 cm
40 cm
60 cm
80 cm
100 cm
Round bar ø 10 mm
Plate
microsonic GmbH • Hauert 16 • D-44227 Dortmund • Tel: +49 2 31 / 97 51 51-0 • Fax: +49 2 31 / 97 51 51-51 • E-Mail: [email protected] • www.microsonic.de